UGIANT

4 / 5

600V indoor building cable l NM-B 600V 12-2 14/2 12-3

stars, based on 0reviews
4999items available

Building Wire Indoor Cable 600volts Copper UL Electrical NM-B 600V 12-2 14/2 12-3 PVC Copper or Aluminum LOW Voltage

Details Show

 

APPLICATIONS
For use primarily in residential wiring, including branch circuits for outlets, switches, etc. May be installed in both exposed and concealed work in normally dry locations. May be installed in air voids of masonry block or tile walls where these walls are not subject to excessive moisture or dampness. May be installed in locations with temperatures up to 90°C, but with the ampacity limited to that of 60°C conductors. Added Circuit: For use primarily in residential wiring for branch circuits supplying outlets located in bedrooms and other areas. Has two separated neutrals so one cable can be used to run two circuits when sharing of a neutral is not allowed.


CONDUCTORS
Solid conductors: Soft, uncoated copper per ASTM-B3
Stranded conductors: Uncoated copper per ASTM-B3 and ASTM B8


CONDUCTOR INSULATION AND JACKET
Color-coded PVC (polyvinyl chloride), rated 90°C dry with clear nylon (polyamide).
Added Circuit: Color-coded PVC rated 90°C: black, white, red and white with red stripe. Insulated conductors also jacketed with clear nylon (polyamide).


GROUNDING CONDUCTOR
Soft, uncoated copper per ASTM-B3


ASSEMBLY
Two-conductor constructions have the insulated conductors laid parallel. Ground
wire is wrapped with paper and laid parallel between the insulated conductors. The
entire construction is wrapped with a paper separator before applying the jacket. Three
-conductor constructions have the insulated conductors twisted together or laid parallel to each
other. Ground wire is wrapped with paper and twisted together or laid parallel to the insulated
conductor.


JACKET
30 mil-thick PVC (polyvinyl chloride) jacket applied over the complete assembly
14-2, 14-2-2 & 14-3 w/ground: white
12-2, 12-2-2 & 12-3 w/ground: yellow
10-2 & 10-3 w/ground: orange
8 AWG or larger: black


INDUSTRY STANDARDS*
UL 83 File

UL 719 Non-Metallic Sheathed Cable File

ASTM-B3
ASTM-B8


TEHCNICAL SPECIFICATION

Conductor Insulation Thickness (mils) Ground Wire Approx. Cable Dimension Approx. Net Wt. Per 1000' Allowable Ampacity
Size (AWG or kcmil) No. of conductors No. of strands Size (AWG) No. of strands (mils) (lbs.)
TWO CONDUCTOR
14 2 1 19 14 1 360X162 57 15
12 2 1 19 12 1 410X179 82 20
10 2 1 24 10 1 494X210 124 30
8 2 7 35 10 1 612X269 186 40
6 2 7 35 10 1 683X304 225 55
THREE CONDUCTOR
14 3 1 19 14 1 307 74 15
12 3 1 19 12 1 347 107 20
10 3 1 24 10 1 422 164 30
8 3 7 35 10 1 565 253 40
6 3 7 35 10 1 650 357 55
4 3 7 46 8 1 814 560 70
2 3 7 46 8 1 952 816 95
FOUR CONDUCTOR
14 2/2 1 19 14 1 336 91 15
14 4 1 19 14 1 336 91 15
12 2/2 1 19 12 1 381 132 20
12 4 1 19 12 1 381 132 20
10 4 1 24 10 1 465 201 30
Model Number:
NM-B wire
Type:
insulated
Application:
building wire
Conductor Material:
Copper
Conductor Type:
Solid
Insulation Material:
PVC
cross section:
14/2AWG
Certification:
UL719
Standard:
UL719
sheathed color:
standard
Conductor:
Copper
Insulation:
PVC
Sheath:
Nylon Sheathed
Product name:
NM-B wire
Keyword:
electrical wire
Usage:
building wire
Recent Reviews
+