UGIANT

4 / 5

UL Copper Indoor Electric Cable Types NM-B 14/2 12/2 10/3

stars, based on 0reviews
9999items available

 

UL   Building Wire  

 

 

 

 

Product Description

 

NMB stands for non-metallic because it has a PVC jacket instead of a metal-clad jacket. It is a basic indoor electrical wire used to deliver power from an electrical box to lights, outlets and appliances. It cannot be used outdoors because the jacket is not prepared to handle wear and tear.

 

 

APPLICATIONS

 NM-B (nonmetallic-sheathed) cable may be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified in the National Electrical Code. NM-B cable is primarily used in residential wiring as branch circuits for outlets, switches, and other loads. NM-B cable may be run in air voids of masonry block or tile walls where such walls are not wet or damp locations. Voltage rating for NM-B cable is 600 volts.

 

CONSTRUCTION

 

 Conductors

Solid 14-10 AWG  soft, uncoated copper, per ASTM-B3;  Stranded 8 AWG conductor and larger uncoated, copper ASTM-B8

 

 Insulation

Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN or THWN-2 with a heat-stabilized Nylon jacket rated for 90°C in dry locations.

 

Grounding Conductor

 Soft, uncoated copper per ASTM-B3 and/or ASTM-B8

 

Jacket

A 30-mil, color-coded, flame retardant and moisture resistant PVC jacket is applied over the completed assembly as follows: 14 AWG White I 12 AWG Yellow I 10 AWG Orange I 8 AWG Black I 6 AWG Black

 

FEATURES:
  • Sizes 14 AWG - 2 AWG
  • Copper building wire
  • Permitted for 600-volt applications
  • Suitable for dry locations
  • RoHS compliant
  •  UL certificat Number:E487898     UL719 standard 

 

STRUCTURE

Conductor: annealed copper, comply to ASTM B3

Insulation: PVC, type THHN.

Color for 2 conductors: white, black;

Color for 3 conductors: white, black, red

Wrapping: kraft paper tape over the grounding conductor

Core jacket: Nylon

Assembly: the conductor laid parallel, with kraft paper tape wrapped.

Jacket: PVC, flame retardant. 90℃.

 
 UL Copper Indoor Electric Cable Types NM-B 14/2 12/2 10/3UL Copper Indoor Electric Cable Types NM-B 14/2 12/2 10/3UL Copper Indoor Electric Cable Types NM-B 14/2 12/2 10/3
Data Sheet:

Size (AWG)       

Number of strands in the conductor  

Insulation
Thickness

mm

Min. Thickness of nylon (mm)

Size of grounding core (AWG)

Jacket thickness (mm)

Approx. OD L*H (mm)

14/2

1

0.38

0.1

14

0.76

4.5*9.1

12/2

1

0.38

0.1

12

0.76

4.9*10.4

10/2

1

0.51

0.1

10

0.76

5.7*12.5

8/2

7

0.76

0.13

10

0.76

7.4*15.9

6/2

7

0.76

0.13

10

0.76

8.4*17.5

14/3

1

0.38

0.1

14

0.76

4.5*11.3

12/3

1

0.38

0.1

12

0.76

4.9*13.4

10/3

1

0.51

0.1

10

0.76

5.7*15.9

8/3

7

0.76

0.13

10

0.76

7.4*21.1

6/3

7

0.76

0.13

10

0.76

8.4*23.9

 


Temperature:
90
Shape:
flat, Round or Flat
Diameter:
14 AWG
Single Wire Size:
size
Model Number:
NM-B Wire
Type:
insulated
Application:
House wire, Residential Wiring
Conductor Material:
Copper
Conductor Type:
Solid
Insulation Material:
PVC
Product name:
Non-Metallic Sheathed Cable
Standard:
UL83 UL719
Voltage::
600 V
Core:
2+1,3+1
Color:
Yellow, white, orange, black
Insulation:
PVC/Nylon/PVC
Wrapping::
Kraft Paper Tape
Leading manufacturer:
wholesale price
Recent Reviews
+