UGIANT
UL LISTED all aluminum alloy stranded conductor single phase cable XHHW XHHW-2 cable
APPLICATION:
1. General purpose wiring for lighting and power - residential, commercial, industrial buildings in accordance with National Electrical Code, maximum conductor temperature of 90°C in wet or dry locations, 600 volts, for installation in conduit or other recognized raceways.
2. Suitable for use in low leakage circuits requiring a dielectric constant of 3.5 or less, such as isolated circuits supplying anesthetizing locations per Article 517-160 of the NEC.
3. Suitable for use as low leakage inductive (loop) vehicle detector wire in accordance with state and municipal requirements.
STANDARDS:
1. Listed by UL as Type XHHW-2 per Standard 44 for Rubber-Insulated Wires and Cables.
2. Conforms to ICEA S-95-658/NEMA WC70, utilizing Column B thicknesses.
3. Conforms to Federal Specification J-C-30B.
CONSTRUCTION: Annealed copper conductor, XLP thermosetting chemically crosslinked polyethylene insulation, surface printed.
Specification
XHHW-2 XLP Insulation, 600 Volts
1. SCOPE
1.1 This specification describes single conductor XHHW-2, a general purpose building wire insulated with
crosslinked polyethylene (XLP) intended for lighting and power circuits at 600 volts or less, in residential,
commercial and industrial buildings. The wire may be operated at 90°C maximum continuous conductor temperature
in wet or dry locations and is listed by Underwriters Laboratories for use in accordance with Article 310
of the National Electrical Code.
2. APPLICABLE STANDARDS
2.1 The following standards form a part of this specification to the extent specified herein:
2.1.1 Underwriters Laboratories Standard 44 for Rubber-Insulated Wires and Cables.
2.1.2 ICEA Pub. No. S-95-658, NEMA Pub. No. WC70 for Nonshielded Power Cables Rated 2000 Volts or Less.
2.1.3 Federal Specification J-C-30B.
3. CONDUCTORS
3.1 Conductors shall be Class B stranded annealed uncoated copper per UL Standard 44.
4. SEPARATOR
4.1 A suitable separator over the conductor may be used at the option of the manufacturer.
5. INSULATION
5.1 Each conductor shall be insulated with XLP, a crosslinked polyethylene complying with the physical and electrical requirements of UL Standard 44 for Type XHHW-2.
5.2 The average thickness of insulation, for a given conductor size, shall be as specified in UL Standard 44 for Type XHHW-2. The minimum thickness at any point shall be not less than 90% of the specified average thickness. The insulation shall be applied tightly to the conductor and shall be free-stripping.
6. IDENTIFICATION
6.1 The wire shall be identified by surface marking indicating manufacturer's identification, conductor size and metal, voltage rating, UL Symbol and type designation.
7. TESTS
7.1 Wire shall be tested in accordance with the requirements of UL Standard 44 for Type XHHW-2.
8. LABELS
8.1 The wire shall bear the Underwriters Laboratories label for Type XHHW-2.
| Size | Stranding | Conductor Diameter | Insulation Thickness | Overall Diameter | Weight | Ampacity at 90C * |
| AWG | (inches) | (inches) | (inches) | LBS/1000' | A | |
| 8 | 7 | 0.134 | 0.045 | 0.227 | 30 | 45 |
| 6 | 7 | 0.169 | 0.045 | 0.262 | 42 | 60 |
| 4 | 7 | 0.213 | 0.045 | 0.306 | 68 | 75 |
| 2 | 7 | 0.268 | 0.045 | 0.361 | 86 | 100 |
| 1 | 7 | 0.299 | 0.55 | 0.412 | 110 | 115 |
| 1/0 | 18 | 0.335 | 0.55 | 0.449 | 134 | 135 |
| 2/0 | 18 | 0.378 | 0.55 | 0.489 | 163 | 150 |
| 3/0 | 18 | 0.423 | 0.55 | 0.536 | 200 | 175 |
| 4/0 | 18 | 0.476 | 0.55 | 0.588 | 247 | 205 |
| 250 | 35 | 0.52 | 0.65 | 0.653 | 296 | 230 |
| 300 | 35 | 0.571 | 0.65 | 0.703 | 359 | 255 |
| 350 | 35 | 0.614 | 0.65 | 0.749 | 401 | 280 |
| 400 | 35 | 0.657 | 0.65 | 0.792 | 453 | 305 |
| 500 | 35 | 0.736 | 0.65 | 0.869 | 556 | 350 |
| 600 | 58 | 0.816 | 0.8 | 0.979 | 679 | 385 |
| 700 | 58 | 0.877 | 0.8 | 1.04 | 782 | 420 |
| 750 | 58 | 0.909 | 0.8 | 1.071 | 833 | 435 |
| 900 | 58 | 0.999 | 0.8 | 1.162 | 987 | 480 |
| 1000 | 58 | 1.059 | 0.8 | 1.223 | 1090 | 500 |
- Model Number:
- XHHW single phase cable
- Insulation Material:
- xlp
- Type:
- LOW VOLTAGE
- Application:
- Overhead
- Conductor Material:
- Aluminum
- Jacket:
- none
- product type:
- XHHW XHHW-2 single phase cable
- certificate:
- UL
- standard:
- UL44
- manufacturer:
- Hebei Huatong
- price:
- wholesale price
- Voltage:
- 600V
- Size:
- 14awg-1000mcm
- characteristic:
- High Heat Water Resistant
- market:
- USA, North America
- Core number:
- single core, multicore