news
Analysis of the real difference between national standard cables and non-standard cables

A sensitive topic that cable practitioners have been familiar with in recent years: it is too difficult to sell national standard cables. They all say that their cables are national standard, and non-standard ones also say their own are national standard. As a result, they have an advantage when quoting. Market practitioners are really helpless;
What is the real difference between the national standard cable and the non-standard cable, you can do a detailed understanding from the following points:
1. Calculate the cost by the weight of copper. It worked at the beginning, but the national standard overlooked a problem. Your copper is an anaerobic rod, but the non-standard one is not. When the weight of the scrap copper and the anaerobic rod is the same, the price of the scrap copper and the anaerobic rod is 10 different. %. Therefore, the national standard cable spent a lot of efforts in propaganda and failed, and the difference between the national standard and the non-standard guarantee was 10%.
2. Cut corners on accessories. The country has increased resistance inspections, and at the same time, it has also stepped up inspections of conventional products. Non-standard cables have begun to work on accessories. If copper accounts for 70% of the cost of cables, then the cost of accessories accounts for about 20%. 20% of the cost, if the materials are slightly inferior, the price difference from the national standard can be 5%. We have also seen that many cables that have been exposed recently have problems with accessories.
3. Short meter of wire to short meter of cable. In fact, the matter of short rice has always existed, which is difficult to check. It used to be common in BV, such as 95-meter line, 98-meter line, or 90-meter line. Now, due to the increase of inspection items, all the products under inspection have been included, so non-standard ones have begun to work in this direction again. I hope everyone will pay attention, 100 meters will be reduced by 1 meter, and 1% of the profit will come out.
4. Thick on both sides and thin in the middle. That is to say, the cables at both ends are national standard, and the middle part is non-standard, so a lot of cost is saved, and the price of the corresponding cable will be much lower. You can't cut the test cable from the middle, so the leak is drilled like this.
At present, the worry is the fourth, as long as the user and the cable manufacturer hide it together, there is no way to check. Do you have to dig the cable out of the ground to measure it? This is also the reason why it is also said to be "national standard", but the price is so different.